Notifications
You must be signed in to change notification settings - Fork 135
BrewPi Device Setup
The setup page is a simplified version of original one of BrewPi. Before the setup, Erase EEPROM
to initialize the EEPROM. Then, list all devices available by Refresh Device List
. Two types of devices are concerned: the sensors and the actuators.
All sensors found by BPL should be listed with temperature readings. Use exclusive Device Slot
number, choose the Function
, and press apply
.
For cooling and heating control, you will need to chose Pin type
, which is Not Inverted for SSR and Inverted for mechanical relays in most case.
After editing and applying all devices, click Refresh Device List
to review the setting. If the assigned devices are not listed in the "installed" section, you might need to Erase EEPROM
and try again.
To uninstall a device, set the Function
to None
.
Wiki is deprecated. Check doc directory for latest document. https://github.com/vitotai/BrewPiLess/tree/master/doc
- Hardware Setup
- Localization of web frontend
- Flash layout and New Frontend
- Software Installation
- WiFi Setup
- System Setup
- Device Setup
- Using Buttons & Menu
- Temperature Logging
- Cloud Logging
- Beer Profile
- iSpindel Support
- Manual Gravity Logging
- Use with Glycol
- Auto Capping(Spunding)
- MQTT Remote Control
- Pressure Monitor and Control
-
Other URLs
- Clear WiFi setting
- Format file system
- OTA update
- Overwrite pages
-
JSON Commands
- Temperature Unit
- Sensor Calibration
- FAQ