-
Notifications
You must be signed in to change notification settings - Fork 0
vmwarecode/VCF-Create-Domain-2
Folders and files
Name | Name | Last commit message | Last commit date | |
---|---|---|---|---|
Repository files navigation
INTRODUCTION: ------------ This module contains script files to create a domain. REQUIREMENTS: ------------ This module requires the following modules: * Python 3 Libraries * requests * sys * json * time * The scripts must be run outside sddc-manager environment. * DNS resolution must be done for sddc-manager. PREREQUSITES: -------------- The following data is required Name of the domain vCenter details ->Name of the vCenter ->Network details ->IP Address of the vCenter ->FQDN of the vCenter ->Gateway ->Subnet mask ->License key for the vCenter ->Password for the root user (8-20 characters) ->Name of the datacenter where vCenter needs to be deployed List of clusters For each cluster ->Name of the cluster ->List of hosts ->For each host ->ID of the host (UUID) ->License key for the host ->List of VDS names to associate with host ->ID of the vmNic host to be associated with VDS, once added to cluster Datastore details NOTE Only one of "vsanDatastoreSpec" (For VSAN) or NFS "nfsDatastoreSpecs" (For NFS) must be specified. For VSAN Number of host failures to tolerate (can be 0, 1, or 2) License key for the vSAN datastore { "vsanDatastoreSpec" : { "failuresToTolerate" : 1, "licenseKey" : "XXXXX-XXXXX-XXXXX-XXXXX-XXXXX", "datastoreName" : "vSanDatastore" } } For NFS List of NFS server names Shared directory path User tag used to annotate NFS share Boolean to identify if the mount directory should be read-only { "nfsDatastoreSpecs" : [ { "nasVolume" : { "serverName" : [ "10.0.0.250" ], "path" : "/nfs_mount/my_read_write_folder", "readOnly" : false }, "datastoreName" : "NFSShare" } ] } Network Details List of VDS details For each VDS Port group names and the corresponding transport type. Note that EDGE_INFRA_OVERLAY_UPLINK, VREALIZE should not be specified in the input spec. DVS host Infrastructure traffic resource type Maximum allowed usage for a traffic class Amount of bandwidth to be reserved for the host infrastructure traffic class NSX cluster Details NOTE Only one of "nsxVClusterSpec" (For NSX-V) or "nsxTClusterSpec" (For NSX-T) must be specified. For NSX-V VLAN ID of the VXLAN License key for NSX VDS to be used for VXLAN traffic/port group. This should belong to one of the VDS being created for the cluster { "nsxVClusterSpec" : { "vlanId" : 3, "vdsNameForVxlanConfig" : "SDDC-Dswitch-Private1" } } For NSX-T VLAN ID of Geneve { "nsxTClusterSpec" : { "geneveVlanId" : 2 } } NSX details NOTE Only one of "nsxVSpec" (For NSX-V) or "nsxTSpec" (For NSX-T) must be specified. For NSX-V NSX Manager virtual machine details Name of the NSX Manager virtual machine Network details IP address of the virtual machine Fully-qualified domain name Gateway Subnet mask NSX-V Controller Details Controller IP addresses (three IPs) without duplicates Controller password Controller gateway Controller subnet mask License key for NSX NSX Manager admin password (basic authorization and SSH) NSX Manager enable password { "nsxManagerSpec" : { "name" : "nsx-manager-2", "networkDetailsSpec" : { "ipAddress" : "10.0.0.44", "dnsName" : "nsx-manager-2.sfo01.rainpole.local", "gateway" : "10.0.0.250", "subnetMask" : "255.255.255.0" } }, "nsxVControllerSpec" : { "nsxControllerIps" : [ "10.0.0.45", "10.0.0.46", "10.0.0.47" ], "nsxControllerPassword" : "Test123456$%", "nsxControllerGateway" : "10.0.0.250", "nsxControllerSubnetMask" : "255.255.255.0" }, "licenseKey" : "XXXXX-XXXXX-XXXXX-XXXXX-XXXXX", "nsxManagerAdminPassword" : "Random0$", "nsxManagerEnablePassword" : "Random0$" } For NSX-T NSX Manager virtual machine details Name of the NSX Manager virtual machine Network details IP Address of the virtual machine Fully-qualified domain name Gateway Subnet mask Virtual IP address which would act as proxy/alias for NSX managers Fully-qualified domain name for VIP so that common SSL certificates can be installed across all managers License key for NSX NSX manager admin Password (basic authorization and SSH) { "nsxManagerSpecs" : [ { "name" : "nsx-manager-2", "networkDetailsSpec" : { "ipAddress" : "10.0.0.44", "dnsName" : "nsx-manager-2.sfo01.rainpole.local", "gateway" : "10.0.0.250", "subnetMask" : "255.255.255.0" } }, { "name" : "nsx-manager-3", "networkDetailsSpec" : { "ipAddress" : "10.0.0.44", "dnsName" : "nsx-manager-2.sfo01.rainpole.local", "gateway" : "10.0.0.250", "subnetMask" : "255.255.255.0" } }, { "name" : "nsx-manager-4", "networkDetailsSpec" : { "ipAddress" : "10.0.0.44", "dnsName" : "nsx-manager-2.sfo01.rainpole.local", "gateway" : "10.0.0.250", "subnetMask" : "255.255.255.0" } } ], "vip" : "10.0.0.166", "vipFqdn" : "vip-nsxmanager.sfo01.rainpole.local", "licenseKey" : "XXXXX-XXXXX-XXXXX-XXXXX-XXXXX", "nsxManagerAdminPassword" : "Random0$" } WARNING NSX details (i.e "nsxVSpec" or "nsxTSpec") must match NSX cluster details (i.e "nsxVClusterSpec" or "nsxTClusterSpec") in the input specification. Network pool should be configured. TIP Refer to Create a Network Pool Hosts should be commissioned. TIP Refer to Commission the Hosts A DHCP server must be configured on the VXLAN VLAN of the management domain. When NSX creates VXLAN VTEPs for the domain, they are assigned IP addresses from the DHCP server. Ensure that host configuration has a minimum of two active vmNics. There must be a free uplink on each host to be used for the domain. USAGE: ----- Sample specification file "domain_creation_spec.json" will be used for domain creation operation. So fill the required details and validate before executing the script. For more information on the provided sample file, please refer to API reference documentation. Usage: python create_domain.py <hostname> <username> <password>
About
No description, website, or topics provided.
Resources
Stars
Watchers
Forks
Releases
No releases published
Packages 0
No packages published