# -*- coding: utf-8 -*- | ||
|
||
# NOTES | ||
# Please see "Add/Request a new BMS" https://louisvdw.github.io/dbus-serialbattery/general/supported-bms#add-by-opening-a-pull-request | ||
# in the documentation for a checklist what you have to do, when adding a new BMS | ||
|
||
# avoid importing wildcards | ||
from battery import Protection, Battery, Cell | ||
from utils import is_bit_set, read_serial_data, logger | ||
import utils | ||
from struct import unpack_from | ||
import sys | ||
|
||
|
||
class SeplosV3(Battery): | ||
def __init__(self, port, baud, address): | ||
super(SeplosV3, self).__init__(port, baud, address) | ||
self.type = self.BATTERYTYPE | ||
|
||
BATTERYTYPE = "SeplosV3" | ||
|
||
def test_connection(self): | ||
# call a function that will connect to the battery, send a command and retrieve the result. | ||
# The result or call should be unique to this BMS. Battery name or version, etc. | ||
# Return True if success, False for failure | ||
result = False | ||
try: | ||
result = self.read_status_data() | ||
# get first data to show in startup log, only if result is true | ||
result = result and self.refresh_data() | ||
except Exception: | ||
( | ||
exception_type, | ||
exception_object, | ||
exception_traceback, | ||
) = sys.exc_info() | ||
file = exception_traceback.tb_frame.f_code.co_filename | ||
line = exception_traceback.tb_lineno | ||
logger.error( | ||
f"Exception occurred: {repr(exception_object)} of type {exception_type} in {file} line #{line}" | ||
) | ||
result = False | ||
|
||
return result | ||
|
||
def unique_identifier(self) -> str: | ||
""" | ||
Used to identify a BMS when multiple BMS are connected | ||
Provide a unique identifier from the BMS to identify a BMS, if multiple same BMS are connected | ||
e.g. the serial number | ||
If there is no such value, please remove this function | ||
""" | ||
return self.serialnumber | ||
|
||
def get_settings(self): | ||
# After successful connection get_settings will be call to set up the battery. | ||
# Set the current limits, populate cell count, etc | ||
# Return True if success, False for failure | ||
|
||
self.capacity = ( | ||
utils.BATTERY_CAPACITY # if possible replace constant with value read from BMS | ||
) | ||
self.max_battery_charge_current = ( | ||
utils.MAX_BATTERY_CHARGE_CURRENT # if possible replace constant with value read from BMS | ||
) | ||
self.max_battery_discharge_current = ( | ||
utils.MAX_BATTERY_DISCHARGE_CURRENT # if possible replace constant with value read from BMS | ||
) | ||
self.max_battery_voltage = utils.MAX_CELL_VOLTAGE * self.cell_count | ||
self.min_battery_voltage = utils.MIN_CELL_VOLTAGE * self.cell_count | ||
|
||
return True | ||
|
||
def refresh_data(self): | ||
# call all functions that will refresh the battery data. | ||
# This will be called for every iteration (1 second) | ||
# Return True if success, False for failure | ||
result = self.read_soc_data() | ||
|
||
return result | ||
|
||
def read_status_data(self): | ||
status_data = self.read_serial_data_template(self.command_status) | ||
# check if connection success | ||
if status_data is False: | ||
return False | ||
|
||
( | ||
self.cell_count, | ||
self.temp_sensors, | ||
self.charger_connected, | ||
self.load_connected, | ||
state, | ||
self.cycles, | ||
) = unpack_from(">bb??bhx", status_data) | ||
|
||
# Integrate a check to be sure, that the received data is from the BMS type you are making this driver for | ||
|
||
self.hardware_version = "TemplateBMS " + str(self.cell_count) + " cells" | ||
logger.info(self.hardware_version) | ||
return True | ||
|
||
def read_soc_data(self): | ||
soc_data = self.read_serial_data_template(self.command_soc) | ||
# check if connection success | ||
if soc_data is False: | ||
return False | ||
|
||
voltage, current, soc = unpack_from(">hxxhh", soc_data) | ||
self.voltage = voltage / 10 | ||
self.current = current / -10 | ||
self.soc = soc / 10 | ||
return True | ||
|
||
def read_serial_data_template(self, command): | ||
# use the read_serial_data() function to read the data and then do BMS spesific checks (crc, start bytes, etc) | ||
data = read_serial_data( | ||
command, self.port, self.baud_rate, self.LENGTH_POS, self.LENGTH_CHECK | ||
) | ||
if data is False: | ||
logger.error(">>> ERROR: No reply - returning") | ||
return False | ||
|
||
start, flag, command_ret, length = unpack_from("BBBB", data) | ||
checksum = sum(data[:-1]) & 0xFF | ||
|
||
if start == 165 and length == 8 and checksum == data[12]: | ||
return data[4 : length + 4] | ||
else: | ||
logger.error(">>> ERROR: Incorrect Reply") | ||
return False |