For evaluation plots, check our jenkins server.
Authors: Antoni Rosinol, Yun Chang, Marcus Abate, Sandro Berchier, Luca Carlone
Kimera-VIO is a Visual Inertial Odometry pipeline for accurate State Estimation from Stereo + IMU data.
We kindly ask to cite our paper if you find this library useful:
- A. Rosinol, M. Abate, Y. Chang, L. Carlone, Kimera: an Open-Source Library for Real-Time Metric-Semantic Localization and Mapping. IEEE Intl. Conf. on Robotics and Automation (ICRA), 2020. arXiv:1910.02490.
@InProceedings{Rosinol20icra-Kimera,
title = {Kimera: an Open-Source Library for Real-Time Metric-Semantic Localization and Mapping},
author = {Rosinol, Antoni and Abate, Marcus and Chang, Yun and Carlone, Luca},
year = {2020},
booktitle = {IEEE Intl. Conf. on Robotics and Automation (ICRA)},
url = {https://github.com/MIT-SPARK/Kimera},
pdf = {https://arxiv.org/pdf/1910.02490.pdf}
}
Backend optimization is based on:
-
C. Forster, L. Carlone, F. Dellaert, and D. Scaramuzza. On-Manifold Preintegration Theory for Fast and Accurate Visual-Inertial Navigation. IEEE Trans. Robotics, 33(1):1-21, 2016.
-
L. Carlone, Z. Kira, C. Beall, V. Indelman, and F. Dellaert. Eliminating Conditionally Independent Sets in Factor Graphs: A Unifying Perspective based on Smart Factors. IEEE Intl. Conf. on Robotics and Automation (ICRA), 2014.
Alternatively, the Regular VIO
backend, using structural regularities, is described in this paper:
- A. Rosinol, T. Sattler, M. Pollefeys, and L. Carlone. Incremental Visual-Inertial 3D Mesh Generation with Structural Regularities. IEEE Int. Conf. on Robotics and Automation (ICRA), 2019.
Tested on Mac, Ubuntu 14.04 & 16.04 & 18.04.
- GTSAM >= 4.0
- OpenCV >= 3.3.1
- OpenGV
- Glog, Gflags
- Gtest (installed automagically).
- DBoW2
- Kimera-RPGO
- ANMS (source files in
src/frontend/feature-detector/anms
, used for adaptive non-max suppression).
Note: if you want to avoid building all dependencies yourself, we provide a docker image that will install them for you. Check installation instructions in docs/kimera_vio_install.md.
Note 2: if you use ROS, then Kimera-VIO-ROS can install all dependencies and Kimera inside a catkin workspace.
Find how to install Kimera-VIO and its dependencies here: Installation instructions.
The LoopClosureDetector (and PGO) module is disabled by default. If you wish to run the pipeline with loop-closure detection enabled, set the use_lcd
flag to true. For the example script, this is done by passing -lcd
at commandline like so:
./scripts/stereoVIOEUROC.bash -lcd
To log output, set the log_output
flag to true. For the script, this is done with the -log
commandline argument. By default, log files will be saved in output_logs.
To run the pipeline in sequential mode (one thread only), set parallel_run
to false. This can be done in the example script with the -s
argument at commandline.
i. Euroc Dataset
- Download one of Euroc's datasets, for example V1_01_easy.zip.
Datasets MH_04 and V2_03 have different number of left/right frames. We suggest using instead our version of Euroc here.
- Unzip the dataset to your preferred directory, for example, in
~/Euroc/V1_01_easy
:
mkdir -p ~/Euroc/V1_01_easy
unzip -o ~/Downloads/V1_01_easy.zip -d ~/Euroc/V1_01_easy
Add %YAML:1.0
at the top of each .yaml
file inside Euroc.
You can do this manually or run the yamelize.bash
script by indicating where the dataset is (it is assumed below to be in ~/path/to/euroc
):
You don't need to yamelize the dataset if you download our version here
cd Kimera-VIO
bash ./scripts/euroc/yamelize.bash -p ~/path/to/euroc
Using a bash script bundling all command-line options and gflags:
cd Kimera-VIO
bash ./scripts/stereoVIOEuroc.bash -p "PATH_TO_DATASET/V1_01_easy"
Alternatively, one may directly use the executable in the build folder:
./build/stereoVIOEuroc
. Nevertheless, check the script./scripts/stereoVIOEuroc.bash
to understand what parameters are expected, or check the parameters section below.
ii. Using ROS wrapper
We provide a ROS wrapper of Kimera-VIO that you can find at: https://github.com/MIT-SPARK/Kimera-VIO-ROS.
This library can be cloned into a catkin workspace and built alongside the ROS wrapper.
For more information on tools for debugging and evaluating the pipeline, see our documentation
We use gtest for unit testing.
To run the unit tests: build the code, navigate inside the build
folder and run testKimeraVIO
:
cd build
./testKimeraVIO
A useful flag is ./testKimeraVIO --gtest_filter=foo
to only run the test you are interested in (regex is also valid).
Alternatively, you can run rosrun kimera_vio run_gtest.py
from anywhere on your system if you've built Kimera-VIO through ROS and sourced the workspace containing Kimera-VIO. This script passes all arguments to testKimeraVIO
, so you should feel free to use whatever flags you would normally use.
Kimera-VIO accepts two independent sources of parameters:
- YAML files: contains parameters for Backend and Frontend.
- gflags contains parameters for all the rest.
To get help on what each gflag parameter does, just run the executable with the --help
flag: ./build/stereoVIOEuroc --help
. You should get a list of gflags similar to the ones here.
- Optionally, you can try the VIO using structural regularities, as in our ICRA 2019 paper, by specifying the option
-r
:./stereoVIOEuroc.bash -p "PATH_TO_DATASET/V1_01_easy" -r
OpenCV's 3D visualization also has some shortcuts for interaction: check tips for usage
We strongly encourage you to submit issues, feedback and potential improvements. We follow the branch, open PR, review, and merge workflow.
To contribute to this repo, ensure your commits pass the linter pre-commit checks.
To enable these checks you will need to install linter.
We also provide a .clang-format
file with the style rules that the repo uses, so that you can use clang-format
to reformat your code.
Also, check tips for development and our developer guide.
If you have problems building or running the pipeline and/or issues with dependencies, you might find useful information in our FAQ or in the issue tracker.
I0512 21:05:55.136549 21233 Pipeline.cpp:449] Statistics
----------- # Log Hz {avg +- std } [min,max]
Data Provider [ms] 0
Display [ms] 146 36.5421 {8.28082 +- 2.40370} [3,213]
VioBackEnd [ms] 73 19.4868 {15.2192 +- 9.75712} [0,39]
VioFrontEnd Frame Rate [ms] 222 59.3276 {5.77027 +- 1.51571} [3,12]
VioFrontEnd Keyframe Rate [ms] 73 19.6235 {31.4110 +- 7.29504} [24,62]
VioFrontEnd [ms] 295 77.9727 {12.1593 +- 10.7279} [3,62]
Visualizer [ms] 73 19.4639 {3.82192 +- 0.805234} [2,7]
backend_input_queue Size [#] 73 18.3878 {1.00000 +- 0.00000} [1,1]
data_provider_left_frame_queue Size (#) 663 165.202 {182.265 +- 14.5110} [1,359]
data_provider_right_frame_queue Size (#) 663 165.084 {182.029 +- 14.5150} [1,359]
display_input_queue Size [#] 146 36.5428 {1.68493 +- 0.00000} [1,12]
stereo_frontend_input_queue Size [#] 301 75.3519 {4.84718 +- 0.219043} [1,5]
visualizer_backend_queue Size [#] 73 18.3208 {1.00000 +- 0.00000} [1,1]
visualizer_frontend_queue Size [#] 295 73.9984 {4.21695 +- 1.24381} [1,7]
#
number of samples taken.Log Hz
average number of samples taken per second in Hz.avg
average of the actual value logged. Same unit as the logged quantity.std
standard deviation of the value logged.[min,max]
minimum and maximum values that the logged value took.
There are two main things logged: the time it takes for the pipeline modules to run (i.e. VioBackEnd
, Visualizer
etc), and the size of the queues between pipeline modules (i.e. backend_input_queue
).
For example:
VioBackEnd [ms] 73 19.4868 {15.2192 +- 9.75712} [0,39]
Shows that the backend runtime got sampled 73
times, at a rate of 19.48
Hz (which accounts for both the time the backend waits for input to consume and the time it takes to process it). That it takes 15.21
ms to consume its input with a standard deviation of 9.75
ms and that the least it took to run for one input was 0
ms and the most it took so far is 39
ms.
For the queues, for example:
stereo_frontend_input_queue Size [#] 301 75.3519 {4.84718 +- 0.219043} [1,5]
Shows that the frontend input queue got sampled 301
times, at a rate of 75.38
Hz. That it stores an average of 4.84
elements, with a standard deviation of 0.21
elements, and that the min size it had was 1
element, and the max size it stored was of 5
elements.
Kimera-VIO is open source under the BSD license, see the LICENSE.BSD file.