Problem:
Logic disks managed by the raid controller will have the same serial number. This results in disks being deduplicated and ignored.
Solution:
From the sample data available the wwn is unique despite the serial number being the same.
The PR adds a minor tweak to continue comparing disks even if serial number is same and check for wwn uniqueness.