Notifications
You must be signed in to change notification settings - Fork 0
Max Cube Binding
Documentation of the MAX!Cube Binding Bundle
Note: This binding has not been released yet. However it is available in the 1.4 Daily Snapshot Builds.
The openHAB MAX!Cube binding allows to connect to ELV MAX!Cube Lan Gateway installations. The binding allows to communicate with the MAX! devices through the MAX!Cube Lan Gateway.
To communicate with MAX! devices, a already setup MAX! environment including a MAX!Cube Lan Gateway is required. In addition, the binding expects an already set up MAX environment.
You need to configure at least the MAX!Cube Lan Gateway IP address in the openhab.cfg file. If not configured via DHCP, the factory default address of the MAX!Cube is 192.168.0.222.
################################ MAX!Cube Binding ##########################################
#
# MAX!Cube LAN gateway IP address
maxcube:ip=192.168.0.222
# MAX!Cube port (Optional, default to 62910)
# maxcube:port=62910
# MAX!Cube refresh interval in ms (Optional, default to 10000)
# maxcube:refreshInterval=10000
Additional you can configure the port the MAX!Cube communicates with openHAB. By default this is 62910 and should not need to be changed.
Furthermore, you can change the refresh interval openHAB communicates with the MAX!Cube. By default the refresh interval is set to 10 seconds.
In order to bind an generic item to the device, you need to provide MAX!Cube configuration settings in your item file (in the folder configurations/items) containing at least the serial number of the device. The syntax of the binding configuration strings accepted is the following:
maxcube="<serialNumber>"
The state of a shutter contact can be retrieved via the generic item binding. To display the shutter state, you need to use a Contact item.
Contact Office_Window "Office Window [MAP(en.map):%s]" (MyGroup) { maxcube="JEQ0650337" }
For a heating thermostat, an identical configuration will provide the setpoint temperature of the heating thermostat (4.5° corresponds to OFF shown on the thermostat display). To show the temperature setpoint you need to use a number item.
Number Heating_Max "Heating Thermostat [%.1f °C]" (MyGroup) { maxcube="JEQ0336148" }
The above examples would be shown as
MAX heating thermostat devices show OFF when turned to the minimum or On when turned to the maximum. The openHAB MAX!Cube binding would show the values 4.5 for OFF and 30.5 for On instead.
If you would like to display OFF and on instead, you can apply a mapping and change the binding using this mapping to
Number Heating_Max "Heating Thermostat [MAP(maxcube.map):%s]" (MyGroup) { maxcube="JEQ0336148" }
Instead of values 4.5 and 30.5 the results would look like
To apply this mapping you need to copy the maxcube.map mapping file into the configuration/transformation folder within the openHAB directory.
Depending on the correpsonding device the MAX!Cube binding can be used to provide specific information about a device instead of the default information.
To receive the valve position of a heating thermostat, the type for the desired information needs to be specified in the bonding configuration
Number Heating_Max_Valve "Thermostat Valve Position [%.1f %%]" (MyGroup) { maxcube="JEQ0336148:type=valve" }
Installation
Community
- Support
- News Archive
- Presentations
- How to Contribute
- IDE Setup
- How to Implement a Binding
- How to Implement an Actions
- User Interfaces
- Classic UI
- iOS Client
- Android Client
- GreenT UI
- Bindings
- Asterisk Binding
- Bluetooth Binding
- Comfo Air Binding
- CUPS Binding
- digitalSTROM Binding
- DMX512 Binding
- EnOcean Binding
- Epson Projector Binding
- Exec Binding
- Fritz!Box Binding
- Fritz AHA Binding
- Homematic Binding
- HTTP Binding
- IHC / ELKO Binding
- KNX Binding
- Koubachi Binding
- MAX!Cube Binding
- MiLight Binding
- Modbus TCP Binding
- MPD Binding
- MQTT Binding
- Network Health Binding
- Nibe Heatpump Binding
- Nikobus Binding
- Novelan/Luxtronic Heatpump Binding
- NTP Binding
- One-Wire Binding
- Onkyo AV Receiver Binding
- OpenSprinkler Binding
- OSGi Configuration Admin Binding
- Philips Hue Binding
- Piface Binding
- Pioneer-AVR-Binding
- Plugwise Binding
- PLCBus Binding
- Pulseaudio Binding
- RFXCOM Binding
- Samsung TV Binding
- Serial Binding
- Snmp Binding
- Squeezebox Binding
- System Info Binding
- Somfy URTSI II Binding
- Sonos Binding
- TCP/UDP Binding
- TinkerForge Binding
- VDR Binding
- Wake-on-LAN Binding
- Z-Wave Binding
- Persistence
- db4o Persistence
- rrd4j Persistence
- Sql Persistence
- Sen.Se Persistence
- Cosm Persistence
- Logging Persistence
- Exec Persistence
- Automation
- Scripts
- Rules
- Actions
- Misc
- REST-API
- Security
- Google Calendar Support
- Twitter Action
- Service Discovery
- Dropbox Bundle
- CometVisu
Samples
- Item definitions
- Sitemap definitions
- Binding configurations
- Rules
- REST Examples
- Tips & Tricks
- FAQ
- XSLT Transforms
- Scripts
- Integration with other applications
- Syntax highlighting for external editors
- Update-Scripts
- Samples-Comfo-Air-Binding
Release Notes